| Assessment Year | 1994 |
|---|---|
| Principal Product | Bricks |
| NAICS |
n/a
|
| SIC | 3251: Brick and Structural Clay Tile |
| Sales Range | $5 M to 10M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 52,000,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $215,526 | 3,623,095 |
kWh
|
$0.059 |
| Natural Gas | $427,606 | 139,828 |
MMBtu
|
$3.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,219 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $2,294 | $2,130 |
$2,294
-
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $5,208 | $9,920 |
$5,208
117,233
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $342 | $700 |
$342
7,034
kWh
|
- | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $29,988 | $15,000 | - |
$29,988
-
MMBtu
|
|
| 05 | 2.4221: Install compressor air intakes in coolest locations | $387 | $200 |
$387
8,206
kWh
|
- | |
| TOTAL RECOMMENDED | $38,219 | $27,950 |
$8,231
132,473
kWh
|
$29,988
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs