| Assessment Year | 2000 |
|---|---|
| Principal Product | pickles |
| NAICS |
n/a
|
| SIC | 2035: Pickled Fruits and Vegetables, Vegetable Sauces and Seasonings, and Salad Dressings |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
73,000
ft2
|
| Annual Production | 60,000,000
lb
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,698 | 2,223,916 |
kWh
|
$0.029 |
| Electricity Demand | $27,503 | 454 |
kW-mo/yr
|
$60.58 |
| Electricity Fees | $(-4,845.0) | - |
|
- |
| Natural Gas | $58,506 | 14,068 |
MMBtu
|
$4.16 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $72,217 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $25,500 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $2,339 | $4,745 |
$1,491
55,393
kWh
|
$848
-
kW-mo/yr
|
- | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $350 | $175 |
$229
8,499
kWh
|
$121
-
kW-mo/yr
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $911 | $80 |
$608
22,567
kWh
|
$303
-
kW-mo/yr
|
- | - | |
| 04 | 3.5217: Reuse / recycle/ sell paper products | $22,500 | - | - | - |
$22,500
-
lb
|
- | |
| 05 | 3.5316: Contract a wood pallet recycling company | $3,000 | - | - | - |
$3,000
-
lb
|
- | |
| 06 | 4.446: Automate finishing process | $25,974 | $767 | - | - | - | $25,974 | |
| 07 | 4.445: Install equipment to move product | $17,143 | $2,100 | - | - | - | $17,143 | |
| TOTAL RECOMMENDED | $72,217 | $7,867 |
$2,328
86,459
kWh
|
$1,272
-
kW-mo/yr
|
$25,500
-
lb
|
$43,117 | ||
| TOTAL IMPLEMENTED | $25,500 | - | - | - |
$25,500
-
lb
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs