Assessment Year | 1999 |
---|---|
Principal Product | Ball Valves and Pneumatic Couplings |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
91,000
ft2
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $102,916 | 1,926,436 |
kWh
|
$0.053 |
Electricity Demand | $13,492 | 549 |
kW-mo/yr
|
$24.58 |
Electricity Fees | $7,709 | - |
|
- |
Natural Gas | $9,314 | 1,867 |
MMBtu
|
$4.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,051,090 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,207 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,388 | $10,745 |
$7,427
129,250
kWh
|
$961
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $5,158 | $6,558 |
$4,526
78,839
kWh
|
$632
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,591 | - |
$1,338
23,447
kWh
|
$253
-
kW-mo/yr
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,308 | $205 |
$1,190
20,809
kWh
|
$118
-
kW-mo/yr
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,545 | $80 |
$2,314
40,445
kWh
|
$231
-
kW-mo/yr
|
- | - | - | |
06 | 2.4314: Use synthetic lubricant | $710 | $174 |
$646
11,137
kWh
|
$64
-
kW-mo/yr
|
- | - | - | |
07 | 3.7198: Reduce / eliminate use of disposable product | $1,440 | $1,440 | - | - |
$1,440
-
lb
|
- | - | |
08 | 4.425: Eliminate/reduce redundant inspections | $6,630 | $1,895 | - | - | - | $6,630 | - | |
09 | 4.651: Install back-up equipment | $1,023,320 | $184,320 | - | - | - | - | $1,023,320 | |
TOTAL RECOMMENDED | $1,051,090 | $205,417 |
$17,441
303,927
kWh
|
$2,259
-
kW-mo/yr
|
$1,440
-
lb
|
$6,630 | $1,023,320 | ||
TOTAL IMPLEMENTED | $10,207 | $8,377 |
$7,700
134,232
kWh
|
$1,067
-
kW-mo/yr
|
$1,440
-
lb
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs