| Assessment Year | 1999 | 
|---|---|
| Principal Product | Plastic Parts, Coils, and Harnesses Used In Acceptors, Chang | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified | 
| Sales Range | $50 M  to 100M  | 
    
| # of Employees | 426 | 
| Plant Area | 
                            95,000
                 
ft2
 
                     | 
    
| Annual Production | 800,000
             
pieces
 
         | 
    
| Production Hrs. Annual | 6,000
             
hrs
 
         | 
    
| Location (State) | Missouri | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $301,720 | 7,639,508 | 
             
kWh
 
         | 
        $0.039 | 
| Electricity Demand | $118,140 | 1,794 | 
             
kW-mo/yr
 
         | 
        $65.85 | 
| Electricity Fees | $23,250 | - | 
             | 
        - | 
| LPG | $41,538 | 9,108 | 
             
MMBtu
 
         | 
        $4.56 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $169,483 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $165,581 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | 
|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.445: Install equipment to move product | $102,637 | $208,000 | - | - | - | $102,637 | - | |
| 02 | 4.454: Modify startup/shutdown times | $59,125 | - | - | - | - | - | $59,125 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,629 | $6,698 | 
                        $1,582
                                                     37,222
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,047
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,190 | $80 | 
                        $729
                                                     17,292
                                 
                                            
kWh
 
                             | 
                                                                                
                        $461
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,669 | $2,622 | 
                        $1,010
                                                     23,740
                                 
                                            
kWh
 
                             | 
                                                                                
                        $659
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 06 | 2.4133: Use most efficient type of electric motors | $1,255 | $2,497 | 
                        $860
                                                     20,223
                                 
                                            
kWh
 
                             | 
                                                                                
                        $395
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 07 | 3.1175: Use a different or recycled raw material | $978 | - | - | - | 
                        $978
                                                     -
                                 
                                            
lb
 
                             | 
                                                                                - | - | |
| TOTAL RECOMMENDED | $169,483 | $219,897 | 
                        $4,181
                                                     98,477
                                 
                                            
kWh
 
                             | 
                                                                                
                        $2,562
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                
                        $978
                                                     -
                                 
                                            
lb
 
                             | 
                                                                                $102,637 | $59,125 | ||
| TOTAL IMPLEMENTED | $165,581 | $214,778 | 
                        $2,311
                                                     54,514
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,508
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | $102,637 | $59,125 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs