Assessment Year | 1998 |
---|---|
Principal Product | Aluminum Die Castings |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $1 M to 5M |
# of Employees | 70 |
Plant Area |
27,500
ft2
|
Annual Production | 1,164,537
lb
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,307 | 1,846,424 |
kWh
|
$0.044 |
Electricity Demand | $10,273 | 408 |
kW-mo/yr
|
$25.18 |
Electricity Fees | $12,137 | - |
|
- |
Natural Gas | $89,276 | 27,713 |
MMBtu
|
$3.22 |
LPG | $3,796 | 266 |
MMBtu
|
$14.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,018 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,501 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.432: Cross-train personnel to avoid lost time | $20 | $4,500 | - | - | - | - | $20 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $129 | $207 |
$104
2,052
kWh
|
$25
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,139 | $1,761 |
$1,038
20,516
kWh
|
$101
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,639 | $80 |
$1,513
29,894
kWh
|
$126
-
kW-mo/yr
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,004 | $57 |
$727
14,361
kWh
|
$277
-
kW-mo/yr
|
- | - | - | |
06 | 2.4133: Use most efficient type of electric motors | $3,209 | $4,403 |
$3,159
62,427
kWh
|
$50
-
kW-mo/yr
|
- | - | - | |
07 | 2.4314: Use synthetic lubricant | $795 | $370 | - | - |
$795
-
gal
|
- | - | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $83 | - | - | - | - |
$83
-
lb
|
- | |
TOTAL RECOMMENDED | $8,018 | $11,378 |
$6,541
129,250
kWh
|
$579
-
kW-mo/yr
|
$795
-
gal
|
$83
-
lb
|
$20 | ||
TOTAL IMPLEMENTED | $5,501 | $10,928 |
$5,028
99,356
kWh
|
$453
-
kW-mo/yr
|
- | - | $20 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |