| Assessment Year | 1998 |
|---|---|
| Principal Product | Toroidal Transformers |
| NAICS |
n/a
|
| SIC | 3612: Power, Distribution, and Specialty Transformers |
| Sales Range | $5 M to 10M |
| # of Employees | 93 |
| Plant Area |
24,000
ft2
|
| Annual Production | 120,000
pieces
|
| Production Hrs. Annual | 2,066
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $32,460 | 804,220 |
kWh
|
$0.040 |
| Electricity Demand | $6,406 | 190 |
kW-mo/yr
|
$33.72 |
| Electricity Fees | $2,644 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,911 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 4.511: Expand operations into unused space | $36,414 | $15,250 | - | - | - | $36,414 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $897 | $2,225 |
$627
14,361
kWh
|
$270
-
kW-mo/yr
|
- | - | |
| 03 | 2.2437: Recover waste heat from equipment | $310 | $343 |
$243
5,569
kWh
|
$67
-
kW-mo/yr
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $187 | $40 |
$153
3,517
kWh
|
$34
-
kW-mo/yr
|
- | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $149 | $47 |
$115
2,638
kWh
|
$34
-
kW-mo/yr
|
- | - | |
| 06 | 3.1163: Use plastic pallets instead of wood | $1,835 | $3,015 | - | - |
$1,835
-
lb
|
- | |
| 07 | 3.7196: Use re-usable filters | $383 | $410 | - | - |
$383
-
lb
|
- | |
| TOTAL RECOMMENDED | $40,175 | $21,330 |
$1,138
26,085
kWh
|
$405
-
kW-mo/yr
|
$2,218
-
lb
|
$36,414 | ||
| TOTAL IMPLEMENTED | $36,911 | $15,633 |
$396
9,086
kWh
|
$101
-
kW-mo/yr
|
- | $36,414 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs