Assessment Year | 1998 |
---|---|
Principal Product | Automobile Glove Box Doors and Instrament Panels |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $50 M to 100M |
# of Employees | 450 |
Plant Area |
82,035
ft2
|
Annual Production | 554,749
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $400,327 | 13,610,199 |
kWh
|
$0.029 |
Electricity Demand | $333,096 | 2,383 |
kW-mo/yr
|
$139.78 |
Electricity Fees | $111,119 | - |
|
- |
Natural Gas | $303,651 | 68,449 |
MMBtu
|
$4.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,003,555 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $86,344 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4314: Use synthetic lubricant | $2,054 | $5,060 | - | - | - | $2,054 | |
02 | 4.611: Begin a practice of predictive / preventative maintenance | $1,725 | $3,200 | - | - | - | $1,725 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $464 | $345 | - | - | - | $464 | |
04 | 2.1321: Replace fossil fuel equipment with electrical equipment | $195 | $590 |
$55
1,465
kWh
|
$140
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,350 | $7,203 |
$2,554
67,995
kWh
|
$2,796
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,666 | $120 |
$2,268
60,375
kWh
|
$1,398
-
kW-mo/yr
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $2,694 | $183 |
$2,554
67,995
kWh
|
$140
-
kW-mo/yr
|
- | - | |
08 | 2.4133: Use most efficient type of electric motors | $9,880 | $15,338 |
$4,988
132,767
kWh
|
$4,892
-
kW-mo/yr
|
- | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,527 | - |
$1,850
49,238
kWh
|
$1,677
-
kW-mo/yr
|
- | - | |
10 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $898,000 | - | - | - |
$898,000
-
lb
|
- | |
11 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $76,000 | - | - | - |
$76,000
-
lb
|
- | |
TOTAL RECOMMENDED | $1,003,555 | $32,039 |
$14,269
379,835
kWh
|
$11,043
-
kW-mo/yr
|
$974,000
-
lb
|
$4,243 | ||
TOTAL IMPLEMENTED | $86,344 | $15,683 |
$4,988
132,767
kWh
|
$4,892
-
kW-mo/yr
|
$76,000
-
lb
|
$464 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs