Assessment Year 2012
Principal Product quartz semiconductor parts
NAICS 334413: Semiconductor and Related Device Manufacturing
SIC 3674: Semiconductors and Related Devices
Sales Range $10
M
to 50
M
# of Employees 55
Plant Area 35,000
ft2
Annual Production 16,695
pieces
Production Hrs. Annual 3,030
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $173,655 2,222,180
kWh
Electricity Demand $52,439 8,328
kW-mo/yr
Electricity Fees $600 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,025 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,430

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.2314: Replace heat treating oven with more efficient unit $23,375 $50,000 $2,750
33,000
kWh
- $20,625
02 2.7142: Utilize higher efficiency lamps and/or ballasts $5,750 $11,600 $4,400
54,100
kWh
$1,350
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,680 $1,000 $2,050
25,200
kWh
$630
-
kW-mo/yr
-
04 2.7124: Make a practice of turning off lights when not needed $220 - $160
2,000
kWh
$60
-
kW-mo/yr
-
TOTAL RECOMMENDED $32,025 $62,600 $9,360
114,300
kWh
$2,040
-
kW-mo/yr
$20,625
TOTAL IMPLEMENTED $8,430 $12,600 $6,450
79,300
kWh
$1,980
-
kW-mo/yr
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs