Assessment Year | 1996 |
---|---|
Principal Product | Heavy Duty Cables |
NAICS |
n/a
|
SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
Sales Range | $10 M to 50M |
# of Employees | 425 |
Plant Area |
70,000
ft2
|
Annual Production | 12,500,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,214 | 3,233,587 |
kWh
|
$0.029 |
Electricity Demand | $82,517 | 8,763 |
kW-mo/yr
|
$9.42 |
Natural Gas | $29,310 | 5,389 |
MMBtu
|
$5.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,059 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,337 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 3.5313: Increase amount of waste recovered for resale | $19,791 | - | - | - |
$19,791
-
lb
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,931 | $80 |
$1,557
54,513
kWh
|
$1,374
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $2,161 | $264 |
$1,149
40,152
kWh
|
$1,012
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,918 | $4,576 |
$914
31,946
kWh
|
$1,004
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $931 | $1,858 |
$478
16,706
kWh
|
$453
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $135 | - |
$105
3,810
kWh
|
$30
-
kW-mo/yr
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $7,603 | $21,012 |
$5,277
184,936
kWh
|
$2,326
-
kW-mo/yr
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $589 | - |
$408
14,361
kWh
|
$181
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $36,059 | $27,790 |
$9,888
346,424
kWh
|
$6,380
-
kW-mo/yr
|
$19,791
-
lb
|
||
TOTAL IMPLEMENTED | $13,337 | $27,710 |
$8,331
291,911
kWh
|
$5,006
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs