Assessment Year | 1996 |
---|---|
Principal Product | Rubber cushion |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
100,000
ft2
|
Annual Production | 11,000,000
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $193,322 | 3,797,773 |
kWh
|
$0.051 |
Electricity Demand | $24,712 | 11,426 |
kW-mo/yr
|
$2.16 |
Natural Gas | $188,317 | 50,338 |
MMBtu
|
$3.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,274 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,873 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,921 | $1,311 |
$1,763
32,825
kWh
|
$158
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,159 | $5,364 |
$1,968
36,635
kWh
|
$191
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $95 | - |
$90
1,758
kWh
|
$5
-
kW-mo/yr
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $5,967 | $9,063 |
$5,561
103,165
kWh
|
$406
-
kW-mo/yr
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,057 | - |
$988
18,464
kWh
|
$69
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,587 | $50 |
$3,355
62,427
kWh
|
$232
-
kW-mo/yr
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $3,341 | $263 |
$3,124
58,030
kWh
|
$217
-
kW-mo/yr
|
- | - | |
08 | 2.4314: Use synthetic lubricant | $1,650 | $140 |
$1,542
28,722
kWh
|
$108
-
kW-mo/yr
|
- | - | |
09 | 2.2437: Recover waste heat from equipment | $16,497 | $41,242 | - | - |
$16,497
-
MMBtu
|
- | |
10 | 3.1163: Use plastic pallets instead of wood | $7,000 | $20,000 | - | - | - |
$7,000
-
lb
|
|
TOTAL RECOMMENDED | $43,274 | $77,433 |
$18,391
342,026
kWh
|
$1,386
-
kW-mo/yr
|
$16,497
-
MMBtu
|
$7,000
-
lb
|
||
TOTAL IMPLEMENTED | $22,873 | $30,687 |
$14,791
274,911
kWh
|
$1,082
-
kW-mo/yr
|
- |
$7,000
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs