Assessment Year 1996
Principal Product Commercial Offset Printing
NAICS
n/a
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 275
Plant Area 60,000
ft2
Annual Production 700,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $124,476 2,577,081
kWh
Electricity Demand $9,586 7,101
kW-mo/yr
Natural Gas $6,572 1,468
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,864 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,619

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Gaseous Waste Savings
01 3.8132: Use less toxic and volatile solvent substitutes $3,746 - - - $3,746
-
lb
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,941 $12,048 $7,623
133,060
kWh
$318
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,374 $1,439 $1,309
22,860
kWh
$65
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $336 - $326
5,569
kWh
$10
-
kW-mo/yr
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $1,245 $90 $1,195
20,809
kWh
$50
-
kW-mo/yr
-
06 2.4221: Install compressor air intakes in coolest locations $1,143 $271 $1,099
19,050
kWh
$44
-
kW-mo/yr
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $79 - $67
1,172
kWh
$12
-
kW-mo/yr
-
TOTAL RECOMMENDED $15,864 $13,848 $11,619
202,520
kWh
$499
-
kW-mo/yr
$3,746
-
lb
TOTAL IMPLEMENTED $14,619 $13,758 $10,424
181,711
kWh
$449
-
kW-mo/yr
$3,746
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Gaseous Waste Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs