| Assessment Year | 1996 |
|---|---|
| Principal Product | Steel Trusses |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
50,000
ft2
|
| Annual Production | 30,000
ton
|
| Production Hrs. Annual | 6,360
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $116,207 | 3,404,748 |
kWh
|
$0.034 |
| Electricity Demand | $11,497 | 7,205 |
kW-mo/yr
|
$1.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,411 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,411 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $532 | $1,107 |
$464
12,016
kWh
|
$68
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $999 | $2,944 |
$859
21,981
kWh
|
$140
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $151 | - |
$144
3,810
kWh
|
$7
-
kW-mo/yr
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $219 | - |
$205
5,275
kWh
|
$14
-
kW-mo/yr
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $1,607 | $4,540 |
$1,467
37,808
kWh
|
$140
-
kW-mo/yr
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $789 | $50 |
$733
18,757
kWh
|
$56
-
kW-mo/yr
|
- | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $907 | $206 |
$844
21,688
kWh
|
$63
-
kW-mo/yr
|
- | |
| 08 | 2.4314: Use synthetic lubricant | $573 | $88 |
$533
13,775
kWh
|
$40
-
kW-mo/yr
|
- | |
| 09 | 3.8143: Recycle cleaning solvent and reuse | $9,634 | $7,700 | - | - |
$9,634
-
gal
|
|
| TOTAL RECOMMENDED | $15,411 | $16,635 |
$5,249
135,110
kWh
|
$528
-
kW-mo/yr
|
$9,634
-
gal
|
||
| TOTAL IMPLEMENTED | $15,411 | $16,635 |
$5,249
135,110
kWh
|
$528
-
kW-mo/yr
|
$9,634
-
gal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs