Assessment Year | 1995 |
---|---|
Principal Product | Headwear |
NAICS |
n/a
|
SIC | 2353: Hats, Caps, and Millinery |
Sales Range | $5 M to 10M |
# of Employees | 275 |
Plant Area |
55,000
ft2
|
Annual Production | 3,400,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $47,287 | 898,300 |
kWh
|
$0.053 |
LPG | $3,646 | 828 |
MMBtu
|
$4.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,394 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,758 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,961 | $8,360 |
$2,961
53,048
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,010 | $2,215 |
$1,010
18,171
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $122 | - |
$122
2,345
kWh
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $660 | $5,530 |
$660
10,844
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $46 | - |
$46
879
kWh
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,292 | $138 |
$1,292
22,274
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $385 | $194 |
$385
6,448
kWh
|
- | - | |
08 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $508 | $1,768 |
$730
11,723
kWh
|
$(-222.0)
-
MMBtu
|
- | |
09 | 2.6121: Reduce hot water temperature to the minimum required | $237 | $10 |
$237
3,810
kWh
|
- | - | |
10 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $3,173 | - | - | - |
$3,173
-
lb
|
|
TOTAL RECOMMENDED | $10,394 | $18,215 |
$7,443
129,542
kWh
|
$(-222.0)
-
MMBtu
|
$3,173
-
lb
|
||
TOTAL IMPLEMENTED | $5,758 | $2,363 |
$2,585
45,134
kWh
|
- |
$3,173
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs