Assessment Year | 1995 |
---|---|
Principal Product | Pasta products |
NAICS |
n/a
|
SIC | 2098: Macaroni, Spaghetti, Vermicelli, and Noodles |
Sales Range | $100 M to 500M |
# of Employees | 300 |
Plant Area |
278,750
ft2
|
Annual Production | 150,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,167,364 | 21,910,903 |
kWh
|
$0.053 |
Natural Gas | $337,137 | 104,200 |
MMBtu
|
$3.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $46,215 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,215 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,268 | $1,595 | - |
$6,268
-
MMBtu
|
- | |
02 | 2.1213: Direct warmest air to combustion intake | $1,585 | $200 | - |
$1,585
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,761 | $2,978 |
$2,761
51,290
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,142 | $8,220 |
$4,142
75,909
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $158 | - |
$158
2,931
kWh
|
- | - | |
06 | 2.4133: Use most efficient type of electric motors | $16,300 | $33,261 |
$16,300
304,807
kWh
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,699 | $225 |
$1,699
31,946
kWh
|
- | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $8,282 | $5,203 |
$8,282
156,800
kWh
|
- | - | |
09 | 2.4314: Use synthetic lubricant | $273 | $80 |
$273
5,275
kWh
|
- | - | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $697 | $100 |
$697
13,189
kWh
|
- | - | |
11 | 3.1192: Reduce scrap production | $4,050 | $300 | - | - |
$4,050
-
lb
|
|
TOTAL RECOMMENDED | $46,215 | $52,162 |
$34,312
642,147
kWh
|
$7,853
-
MMBtu
|
$4,050
-
lb
|
||
TOTAL IMPLEMENTED | $46,215 | $52,162 |
$34,312
642,147
kWh
|
$7,853
-
MMBtu
|
$4,050
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs