Assessment Year | 1995 |
---|---|
Principal Product | Coffee |
NAICS |
n/a
|
SIC | 2095: Roasted Coffee |
Sales Range | $50 M to 100M |
# of Employees | 88 |
Plant Area |
100,000
ft2
|
Annual Production | 22,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $159,702 | 2,466,882 |
kWh
|
$0.065 |
Natural Gas | $114,200 | 30,862 |
MMBtu
|
$3.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,683 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,683 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $(-5,373.0) | $4,944 |
$1,857
28,429
kWh
|
$(-7,230.0)
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $778 | $1,236 |
$778
12,016
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $3,125 | $6,209 |
$3,125
48,945
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $297 | - |
$297
4,689
kWh
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $3,265 | $215 |
$3,265
52,169
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $152 | $100 |
$152
2,345
kWh
|
- | |
07 | 2.4226: Use / purchase optimum sized compressor | $6,040 | $182 |
$6,040
93,787
kWh
|
- | |
08 | 2.6121: Reduce hot water temperature to the minimum required | $170 | $20 |
$150
2,052
kWh
|
$20
-
MMBtu
|
|
09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $229 | $500 |
$296
4,396
kWh
|
$(-67.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,683 | $13,406 |
$15,960
248,828
kWh
|
$(-7,277.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,683 | $13,406 |
$15,960
248,828
kWh
|
$(-7,277.0)
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs