Assessment Year 1995
Principal Product heating systems and equipments
NAICS
n/a
SIC 3567: Industrial Process Furnaces and Ovens
Sales Range $50
M
to 100
M
# of Employees 316
Plant Area 150,000
ft2
Annual Production 700
thousand feet
Production Hrs. Annual 2,080
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $262,183 3,565,065
kWh
Natural Gas $38,723 7,558
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,627 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,044

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings
01 3.4114: Replace city water with recycled water via cooling tower $17,228 $23,100 $(-1,502.0)
(-20,516)
kWh
- $18,730
-
Tgal
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,795 $40,300 $9,795
133,353
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,560 $870 $1,560
21,102
kWh
- -
04 2.4133: Use most efficient type of electric motors $2,920 $8,974 $2,920
39,859
kWh
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $754 $725 $754
10,258
kWh
- -
06 2.4221: Install compressor air intakes in coolest locations $789 $634 $789
10,844
kWh
- -
07 2.4314: Use synthetic lubricant $420 $96 $420
5,862
kWh
- -
08 2.6121: Reduce hot water temperature to the minimum required $161 $150 - $161
-
MMBtu
-
TOTAL RECOMMENDED $33,627 $74,849 $14,736
200,762
kWh
$161
-
MMBtu
$18,730
-
Tgal
TOTAL IMPLEMENTED $5,044 $10,579 $4,883
66,823
kWh
$161
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs