Assessment Year | 1994 |
---|---|
Principal Product | conveyor belts |
NAICS |
n/a
|
SIC | 3052: Rubber and Plastics Hose and Belting |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
198,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $151,118 | 2,296,014 |
kWh
|
$0.066 |
Natural Gas | $34,711 | 7,011 |
MMBtu
|
$4.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,452 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,514 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|
01 | 3.4114: Replace city water with recycled water via cooling tower | $5,780 | $1,580 |
$(-420.0)
(-6,448)
kWh
|
- |
$6,200
-
Tgal
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,750 | $675 |
$1,750
26,671
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,612 | $2,530 |
$1,612
24,619
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,545 | $200 |
$1,545
23,447
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $285 | $439 |
$285
4,396
kWh
|
- | - | |
06 | 2.4133: Use most efficient type of electric motors | $4,114 | $8,337 |
$4,114
62,427
kWh
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $647 | $200 |
$647
9,965
kWh
|
- | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $1,412 | $490 |
$1,412
21,395
kWh
|
- | - | |
09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $938 | $2,385 |
$938
4,103
kWh
|
- | - | |
10 | 2.4314: Use synthetic lubricant | $733 | $208 |
$733
11,137
kWh
|
- | - | |
11 | 2.1233: Analyze flue gas for proper air/fuel ratio | $636 | $1,195 | - |
$636
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $19,452 | $18,239 |
$12,616
181,712
kWh
|
$636
-
MMBtu
|
$6,200
-
Tgal
|
||
TOTAL IMPLEMENTED | $18,514 | $15,854 |
$11,678
177,609
kWh
|
$636
-
MMBtu
|
$6,200
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs