ITAC Assessment: MO0107
ITAC logo
ITAC Assessment: MO0107
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Office Filing Supplies
NAICS
n/a
SIC 2522: Office Furniture, Except Wood
Sales Range $50
M
to 100
M
# of Employees 400
Plant Area 326,000
ft2
Annual Production 84,000,000
lb
Production Hrs. Annual 6,300
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $385,008 7,169,695
kWh
Natural Gas $7,285 1,584
MMBtu
LPG $26,930 3,913
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $105,371 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,518

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7231: Use radiant heater for spot heating $56,232 $47,580 $56,232
504,396
kWh
- -
02 2.7243: Improve air circulation with destratification fans / other methods $13,754 $17,627 $13,754
256,155
kWh
- -
03 2.2511: Insulate bare equipment $1,914 $2,341 $1,914
35,756
kWh
- -
04 2.8113: Purchase gas directly from a contract gas supplier $10,357 $300 - - $10,357
05 2.7142: Utilize higher efficiency lamps and/or ballasts $5,689 $16,563 $5,689
105,803
kWh
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,418 $641 $2,418
45,135
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $277 $728 $277
5,275
kWh
- -
08 2.4133: Use most efficient type of electric motors $5,508 $12,224 $5,508
102,579
kWh
- -
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,301 $775 $1,301
24,326
kWh
- -
10 2.4221: Install compressor air intakes in coolest locations $3,211 $3,010 $3,211
59,789
kWh
- -
11 2.4231: Reduce the pressure of compressed air to the minimum required $3,088 $250 $3,088
57,444
kWh
- -
12 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,162 $1,547 $1,831
33,998
kWh
$(-669.0)
-
MMBtu
-
13 2.6121: Reduce hot water temperature to the minimum required $460 $40 $460
8,499
kWh
- -
TOTAL RECOMMENDED $105,371 $103,626 $95,683
1,239,155
kWh
$(-669.0)
-
MMBtu
$10,357
TOTAL IMPLEMENTED $14,518 $23,304 $15,187
282,825
kWh
$(-669.0)
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs