ITAC Assessment: MO0095
ITAC logo
ITAC Assessment: MO0095
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product Fractional-Horsepower Electric Motor
NAICS
n/a
SIC 3621: Motors and Generators
Sales Range $10
M
to 50
M
# of Employees 502
Plant Area 270,000
ft2
Annual Production 1,378,000
pieces
Production Hrs. Annual 6,192
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $750,745 14,246,483
kWh
Natural Gas $42,328 6,616
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $19,004 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,697

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $6,458 $22,197 $6,458
122,509
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,402 $956 $3,402
64,478
kWh
-
03 2.4221: Install compressor air intakes in coolest locations $2,717 $2,246 $2,717
51,583
kWh
-
04 2.4314: Use synthetic lubricant $1,296 $576 $1,296
24,619
kWh
-
05 2.4133: Use most efficient type of electric motors $1,709 $3,831 $1,709
32,532
kWh
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $411 $105 $411
7,913
kWh
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $463 $629 $463
8,792
kWh
-
08 2.8113: Purchase gas directly from a contract gas supplier $2,548 $300 - $2,548
TOTAL RECOMMENDED $19,004 $30,840 $16,456
312,426
kWh
$2,548
TOTAL IMPLEMENTED $14,697 $29,335 $14,697
279,015
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs