Assessment Year | 1993 |
---|---|
Principal Product | Electric Motors |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $50 M to 100M |
# of Employees | 502 |
Plant Area |
96,000
ft2
|
Annual Production | 1,300,000
pieces
|
Production Hrs. Annual | 5,880
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $333,687 | 8,022,274 |
kWh
|
$0.042 |
LPG | $7,551 | 1,396 |
MMBtu
|
$5.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,225 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,953 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $5,587 | $2,155 |
$5,587
134,232
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $2,582 | $2,804 |
$2,582
62,134
kWh
|
|
03 | 2.4314: Use synthetic lubricant | $1,614 | $1,245 |
$1,614
38,687
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,655 | $14,813 |
$5,655
135,991
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $2,515 | $7,131 |
$2,515
60,375
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $366 | $245 |
$366
8,792
kWh
|
|
07 | 2.2414: Use waste heat from hot flue gases to preheat | $10,030 | $23,000 |
$10,030
241,208
kWh
|
|
08 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $13,876 | $3,216 |
$13,876
(-187,280)
kWh
|
|
TOTAL RECOMMENDED | $42,225 | $54,609 |
$42,225
494,139
kWh
|
||
TOTAL IMPLEMENTED | $17,953 | $28,148 |
$17,953
431,419
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs