Assessment Year | 1993 |
---|---|
Principal Product | Air Conditioners and Baseboard Heate |
NAICS |
n/a
|
SIC | 3634: Electric Housewares and Fans |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
300,000
ft2
|
Annual Production | 255,000
pieces
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $318,104 | 4,839,097 |
kWh
|
$0.066 |
Natural Gas | $162,538 | 42,591 |
MMBtu
|
$3.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,345 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,686 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $22,701 | $8,000 | - | $22,701 | |
02 | 2.4221: Install compressor air intakes in coolest locations | $4,251 | $2,550 |
$4,251
64,771
kWh
|
- | |
03 | 2.4314: Use synthetic lubricant | $2,068 | $1,920 |
$2,068
31,360
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,403 | $200 |
$1,403
21,395
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $4,132 | $13,043 |
$4,132
62,720
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,984 | $1,095 |
$1,984
30,188
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,692 | $16,551 |
$4,692
71,219
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,129 | $727 |
$2,129
32,532
kWh
|
- | |
09 | 2.8123: Pay utility bills on time | $985 | - | - | $985 | |
TOTAL RECOMMENDED | $44,345 | $44,086 |
$20,659
314,185
kWh
|
$23,686 | ||
TOTAL IMPLEMENTED | $23,686 | $8,000 | - | $23,686 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs