| Assessment Year | 1993 |
|---|---|
| Principal Product | Steel Castings |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $5 M to 10M |
| # of Employees | 90 |
| Plant Area |
110,500
ft2
|
| Annual Production | 3,800,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $241,152 | 4,143,318 |
kWh
|
$0.058 |
| Natural Gas | $48,149 | 12,992 |
MMBtu
|
$3.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,800 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,800 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $1,143 | $1,605 |
$1,143
19,637
kWh
|
|
| 02 | 2.4314: Use synthetic lubricant | $1,117 | $650 |
$1,117
19,343
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $885 | $5,143 |
$885
15,240
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $750 | $385 |
$750
12,896
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $905 | $4,520 |
$905
15,533
kWh
|
|
| TOTAL RECOMMENDED | $4,800 | $12,303 |
$4,800
82,649
kWh
|
||
| TOTAL IMPLEMENTED | $4,800 | $12,303 |
$4,800
82,649
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs