| Assessment Year | 1992 |
|---|---|
| Principal Product | ELECTRIC MOTORS |
| NAICS |
n/a
|
| SIC | 3621: Motors and Generators |
| Sales Range | $5 M to 10M |
| # of Employees | 85 |
| Plant Area |
n/a
|
| Annual Production | 40,000
pieces
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $59,572 | 854,338 |
kWh
|
$0.070 |
| LPG | $10,529 | 1,458 |
MMBtu
|
$7.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,165 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $643 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $328 | $6,500 |
$328
4,689
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $948 | $370 |
$948
13,482
kWh
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $643 | $150 |
$643
9,379
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $312 | $670 |
$312
4,396
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $677 | $5,000 |
$677
9,672
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $764 | $332 |
$868
12,603
kWh
|
$(-104.0) | |
| 07 | 3.4115: Recover and reuse cooling water | $1,493 | - |
$54
879
kWh
|
$1,439 | |
| TOTAL RECOMMENDED | $5,165 | $13,022 |
$3,830
55,100
kWh
|
$1,335 | ||
| TOTAL IMPLEMENTED | $643 | $150 |
$643
9,379
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs