Assessment Year | 1992 |
---|---|
Principal Product | ELECTRIC MOTORS |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
n/a
|
Annual Production | 40,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $59,572 | 854,338 |
kWh
|
$0.070 |
LPG | $10,529 | 1,458 |
MMBtu
|
$7.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,165 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $643 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $328 | $6,500 |
$328
4,689
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $948 | $370 |
$948
13,482
kWh
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $643 | $150 |
$643
9,379
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $312 | $670 |
$312
4,396
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $677 | $5,000 |
$677
9,672
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $764 | $332 |
$868
12,603
kWh
|
$(-104.0) | |
07 | 3.4115: Recover and reuse cooling water | $1,493 | - |
$54
879
kWh
|
$1,439 | |
TOTAL RECOMMENDED | $5,165 | $13,022 |
$3,830
55,100
kWh
|
$1,335 | ||
TOTAL IMPLEMENTED | $643 | $150 |
$643
9,379
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs