| Assessment Year | 1992 |
|---|---|
| Principal Product | STEEL PIPE AND TUBING |
| NAICS |
n/a
|
| SIC | 3317: Steel Pipe and Tubes |
| Sales Range | $10 M to 50M |
| # of Employees | 132 |
| Plant Area |
n/a
|
| Annual Production | 80,000
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $446,695 | 7,470,985 |
kWh
|
$0.060 |
| LPG | $80,685 | 14,399 |
MMBtu
|
$5.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,980 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,261 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,173 | $775 |
$3,470
58,324
kWh
|
$(-297.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,452 | $2,832 |
$1,452
24,326
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $962 | $2,230 |
$962
16,120
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $322 | - |
$322
5,569
kWh
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,377 | $5,400 |
$2,377
39,859
kWh
|
- | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $3,975 | $1,600 |
$3,975
66,823
kWh
|
- | |
| 07 | 2.4312: Improve lubrication practices | $2,719 | - |
$2,719
45,721
kWh
|
- | |
| TOTAL RECOMMENDED | $14,980 | $12,837 |
$15,277
256,742
kWh
|
$(-297.0) | ||
| TOTAL IMPLEMENTED | $12,261 | $12,837 |
$12,558
211,021
kWh
|
$(-297.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs