Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $89,625 | 1,711,606 |
kWh
|
$0.052 |
| LPG | $82,068 | 15,692 |
MMBtu
|
$5.23 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,479 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,183 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $677 | $755 |
$677
12,896
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,646 | - |
$1,646
31,360
kWh
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,770 | $40 |
$1,770
33,705
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,183 | $292 |
$1,183
22,567
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $313 | $507 |
$313
5,862
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $890 | $283 |
$993
19,050
kWh
|
$(-103.0) | |
| TOTAL RECOMMENDED | $6,479 | $1,877 |
$6,582
125,440
kWh
|
$(-103.0) | ||
| TOTAL IMPLEMENTED | $1,183 | $292 |
$1,183
22,567
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs