| Assessment Year | 1991 |
|---|---|
| Principal Product | FIRE BRICK |
| NAICS |
n/a
|
| SIC | 3255: Clay Refractories |
| Sales Range | $10 M to 50M |
| # of Employees | 104 |
| Plant Area |
n/a
|
| Annual Production | 7,700,000
pieces
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $398,558 | 6,282,532 |
kWh
|
$0.063 |
| Natural Gas | $407,446 | 166,560 |
MMBtu
|
$2.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $50,203 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 3.4115: Recover and reuse cooling water | $28,978 | - |
$216
3,517
kWh
|
$28,762 | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,765 | - |
$7,765
122,509
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $1,143 | $2,738 |
$1,143
17,878
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,499 | - |
$1,581
24,912
kWh
|
$(-82.0) | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $376 | $300 |
$376
5,862
kWh
|
- | |
| 06 | 2.4321: Upgrade obsolete equipment | $2,924 | - |
$2,924
46,014
kWh
|
- | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $7,518 | $416 |
$7,518
118,406
kWh
|
- | |
| TOTAL RECOMMENDED | $50,203 | $3,454 |
$21,523
339,098
kWh
|
$28,680 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs