Assessment Year | 1991 |
---|---|
Principal Product | FIRE BRICK |
NAICS |
n/a
|
SIC | 3255: Clay Refractories |
Sales Range | $10 M to 50M |
# of Employees | 104 |
Plant Area |
n/a
|
Annual Production | 7,700,000
pieces
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $398,558 | 6,282,532 |
kWh
|
$0.063 |
Natural Gas | $407,446 | 166,560 |
MMBtu
|
$2.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,203 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 3.4115: Recover and reuse cooling water | $28,978 | - |
$216
3,517
kWh
|
$28,762 | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,765 | - |
$7,765
122,509
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $1,143 | $2,738 |
$1,143
17,878
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,499 | - |
$1,581
24,912
kWh
|
$(-82.0) | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $376 | $300 |
$376
5,862
kWh
|
- | |
06 | 2.4321: Upgrade obsolete equipment | $2,924 | - |
$2,924
46,014
kWh
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $7,518 | $416 |
$7,518
118,406
kWh
|
- | |
TOTAL RECOMMENDED | $50,203 | $3,454 |
$21,523
339,098
kWh
|
$28,680 | ||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs