| Assessment Year | 2025 |
|---|---|
| Principal Product | Bread and Pastry |
| NAICS | 311211: Flour Milling |
| SIC | 2041: Flour and Other Grain Mill Products |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
24,000
ft2
|
| Annual Production | 19,760,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Puerto Rico |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $934,388 | 4,272,840 |
kWh
|
$0.22 |
| Electricity Demand | $94,954 | 10,028 |
kW-mo/yr
|
$9.47 |
| Electricity Fees | $5,370 | - |
|
- |
| TOTAL YEARLY COSTS | $1,034,712 | |||
| RECOMMENDED SAVINGS* | $144,191 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $53,117 | $3,200 | - | - | $53,117 | |
| 02 | 2.7221: Lower temperature during the winter season and vice-versa | $46,085 | $240 |
$43,508
198,667
kWh
|
$2,577
-
kW-mo/yr
|
- | |
| 03 | 2.3212: Optimize plant power factor | $13,405 | $29,632 | - |
$13,405
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,111 | $1,620 |
$9,316
42,541
kWh
|
$795
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,837 | $3,373 |
$6,312
28,823
kWh
|
$525
-
kW-mo/yr
|
- | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,938 | $8,638 |
$5,606
25,598
kWh
|
$332
-
kW-mo/yr
|
- | |
| 07 | 2.8114: Change rate schedules or other changes in utility service | $4,172 | $100 | - | - | $4,172 | |
| 08 | 2.2511: Insulate bare equipment | $3,469 | $1,976 |
$3,275
14,955
kWh
|
$194
-
kW-mo/yr
|
- | |
| 09 | 2.7135: Install occupancy sensors | $1,057 | $1,380 |
$1,057
4,826
kWh
|
- | - | |
| TOTAL RECOMMENDED | $144,191 | $50,159 |
$69,074
315,410
kWh
|
$17,828
-
kW-mo/yr
|
$57,289 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs