| Assessment Year | 2024 |
|---|---|
| Principal Product | Aircraft Parts |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 150 |
| Plant Area |
28,600
ft2
|
| Annual Production | 6,000
units
|
| Production Hrs. Annual | 2,808
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,087 | 925,191 |
kWh
|
$0.071 |
| Electricity Demand | $61,203 | 4,807 |
kW-mo/yr
|
$12.73 |
| Electricity Fees | $26,275 | - |
|
- |
| TOTAL YEARLY COSTS | $153,565 | |||
| RECOMMENDED SAVINGS* | $25,348 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $23,119 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $7,947 | $700 |
$4,689
68,712
kWh
|
$3,738
-
kW-mo/yr
|
$(-480.0) | |
| 02 | 2.7442: Keep doors and windows shut when not on use | $7,135 | $200 |
$4,041
56,913
kWh
|
$3,094
-
kW-mo/yr
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $4,793 | - |
$12,093
170,329
kWh
|
- | $(-7,300.0) | |
| 04 | 2.7425: Clean or color roof to reduce solar load | $2,229 | $3,301 |
$1,261
17,761
kWh
|
$968
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,923 | $4,108 |
$1,089
15,332
kWh
|
$834
-
kW-mo/yr
|
- | |
| 06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,321 | $911 |
$1,061
14,940
kWh
|
$260
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $25,348 | $9,220 |
$24,234
343,987
kWh
|
$8,894
-
kW-mo/yr
|
$(-7,780.0) | ||
| TOTAL IMPLEMENTED | $23,119 | $5,919 |
$22,973
326,226
kWh
|
$7,926
-
kW-mo/yr
|
$(-7,780.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs