Assessment Year 2024
Principal Product Fabricated Metal Parts
NAICS 332710: Machine Shops
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 78,000
ft2
Annual Production 100,220
pieces
Production Hrs. Annual 8,008
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $163,959 2,411,040
kWh
Electricity Demand $65,994 5,184
kW-mo/yr
Electricity Fees $38,135 -
Waste Disposal Costs
Water Usage $2,381 405
Tgal
Water Disposal $3,548 405
Tgal
TOTAL YEARLY COSTS $274,017
RECOMMENDED SAVINGS* $648,732 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Increase in Production Savings
01 2.4321: Upgrade obsolete equipment $636,028 $600,000 $(-6,920.0)
(-101,764)
kWh
$7,180
-
kW-mo/yr
- $635,768
02 2.7221: Lower temperature during the winter season and vice-versa $5,522 $700 $4,687
68,929
kWh
$1,315
-
kW-mo/yr
$(-480.0) -
03 2.4239: Eliminate or reduce compressed air usage $2,651 $7,497 $2,065
30,347
kWh
$586
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,899 $1,980 $1,511
22,216
kWh
$388
-
kW-mo/yr
- -
05 2.4231: Reduce the pressure of compressed air to the minimum required $1,840 $3,750 $1,458
21,840
kWh
$382
-
kW-mo/yr
- -
06 2.7442: Keep doors and windows shut when not on use $792 $320 $160
2,359
kWh
$632
-
kW-mo/yr
- -
TOTAL RECOMMENDED $648,732 $614,247 $2,961
43,927
kWh
$10,483
-
kW-mo/yr
$(-480.0) $635,768
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs