Assessment Year | 2024 |
---|---|
Principal Product | Woodwork |
NAICS | 337212: Custom Architectural Woodwork and Millwork Manufacturing |
SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
60,000
ft2
|
Annual Production | 30,000,000
pieces
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $63,553 | 945,910 |
kWh
|
$0.067 | |
Electricity Demand | $57,107 | 4,474 |
kW-mo/yr
|
$12.76 | |
Electricity Fees | $22,676 | - |
|
- | |
Fuel Oil #1 | $2,400 | 82 |
MMBtu
|
$29.27 | |
Waste Disposal Costs | |||||
Water Usage | $17,607 | 1,879 |
Tgal
|
$9.37 | |
Water Disposal | $23,863 | 1,879 |
Tgal
|
$12.70 | |
TOTAL YEARLY COSTS | $187,206 | ||||
RECOMMENDED SAVINGS* | $46,927 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $12,690 | $26,240 |
$7,329
109,394
kWh
|
$5,361
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $10,226 | $1,016 |
$6,281
93,751
kWh
|
$3,945
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,757 | $1,980 |
$5,634
84,085
kWh
|
$4,123
-
kW-mo/yr
|
- | - | - | |
04 | 4.522: Modify storage space to avoid rental of a warehouse | $5,488 | $965 |
$2,075
30,965
kWh
|
$1,213
-
kW-mo/yr
|
- | - | $2,200 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,005 | $9,012 |
$1,520
22,689
kWh
|
$1,485
-
kW-mo/yr
|
- | - | - | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $2,309 | $5,731 |
$1,786
26,651
kWh
|
$523
-
kW-mo/yr
|
- | - | - | |
07 | 3.4151: Minimize water usage | $1,521 | $800 | - | - |
$646
-
Tgal
|
$875
-
Tgal
|
- | |
08 | 2.7444: Close holes and openings in building such as broken windows | $729 | $34 |
$369
5,500
kWh
|
$360
-
kW-mo/yr
|
- | - | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $717 | $2,430 |
$414
6,178
kWh
|
$303
-
kW-mo/yr
|
- | - | - | |
10 | 2.7135: Install occupancy sensors | $485 | $903 |
$485
7,245
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $46,927 | $49,111 |
$25,893
386,458
kWh
|
$17,313
-
kW-mo/yr
|
$646
-
Tgal
|
$875
-
Tgal
|
$2,200 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs