Assessment Year 2023
Principal Product Printed material
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 160
Plant Area 96,000
ft2
Annual Production 36,000,000
pieces
Production Hrs. Annual 4,290
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $252,030 3,766,835
kWh
Electricity Demand $146,332 12,084
kW-mo/yr
Electricity Fees $70,540 -
TOTAL YEARLY COSTS $468,902
RECOMMENDED SAVINGS* $89,998 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $56,597

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.6218: Turn off equipment when not in use $31,593 - $31,593
471,535
kWh
-
02 2.7232: Replace existing hvac unit with high efficiency model $12,768 $62,963 $8,481
126,586
kWh
$4,287
-
kW-mo/yr
03 2.7442: Keep doors and windows shut when not on use $11,974 - $7,953
118,699
kWh
$4,021
-
kW-mo/yr
04 2.7221: Lower temperature during the winter season and vice-versa $7,404 $630 $5,939
88,638
kWh
$1,465
-
kW-mo/yr
05 2.7229: Air condition only space necessary $5,093 $4,315 $3,524
52,604
kWh
$1,569
-
kW-mo/yr
06 2.7273: Install desiccant humidity control system $4,219 $12,866 $3,383
50,493
kWh
$836
-
kW-mo/yr
07 2.2312: Minimize non-essential material in heat treatment process $3,449 $1,600 $3,449
51,480
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $3,373 $2,640 $2,259
33,711
kWh
$1,114
-
kW-mo/yr
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,177 $1,660 $1,693
25,268
kWh
$484
-
kW-mo/yr
10 2.7135: Install occupancy sensors $2,010 $1,344 $2,010
29,995
kWh
-
11 2.7444: Close holes and openings in building such as broken windows $1,774 $205 $1,178
17,588
kWh
$596
-
kW-mo/yr
12 2.7447: Install vinyl strip / high speed / air curtain doors $1,713 $6,180 $1,138
16,989
kWh
$575
-
kW-mo/yr
13 2.4239: Eliminate or reduce compressed air usage $1,450 $2,090 $1,123
16,768
kWh
$327
-
kW-mo/yr
14 2.7424: Shade windows from summer sun $1,001 $1,664 $662
9,880
kWh
$339
-
kW-mo/yr
TOTAL RECOMMENDED $89,998 $98,157 $74,385
1,110,234
kWh
$15,613
-
kW-mo/yr
TOTAL IMPLEMENTED $56,597 $3,890 $50,627
755,620
kWh
$5,970
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs