Assessment Year 2023
Principal Product Cattle head
NAICS 311611: Animal (except Poultry) Slaughtering
SIC 2011: Meat Packing Plants
Sales Range $5
M
to 10
M
# of Employees 140
Plant Area 66,000
ft2
Annual Production 36,000
units
Production Hrs. Annual 8,736
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $579,899 6,587,400
kWh
Electricity Demand $88,662 13,039
kW-mo/yr
Electricity Fees $12,435 -
Natural Gas $285,550 12,058
MMBtu
Waste Disposal Costs
Solid Waste (non-haz) $246,000 3,888,000
lb
TOTAL YEARLY COSTS $1,212,546
RECOMMENDED SAVINGS* $188,818 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $119,773

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings One-time Revenue or Avoided Cost Savings
01 2.7221: Lower temperature during the winter season and vice-versa $65,480 $580 $59,197
672,692
kWh
$6,283
-
kW-mo/yr
- - -
02 2.1133: Adjust burners for efficient operation $25,315 $1,760 - - $25,315
-
MMBtu
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $24,929 $163,200 $22,535
256,075
kWh
$2,394
-
kW-mo/yr
- - -
04 3.6192: Use a less expensive method of waste removal $22,620 $52,100 - - - $22,620
-
lb
-
05 2.6218: Turn off equipment when not in use $15,797 - $15,797
179,507
kWh
- - - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $14,309 $1,980 $12,935
146,992
kWh
$1,374
-
kW-mo/yr
- - -
07 2.9114: Use solar heat to make electricty $13,017 $86,104 $8,046
91,456
kWh
$4,971
-
kW-mo/yr
- - -
08 2.7447: Install vinyl strip / high speed / air curtain doors $5,784 $3,190 $5,226
59,383
kWh
$558
-
kW-mo/yr
- - -
09 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,456 $280 $1,316
14,956
kWh
$140
-
kW-mo/yr
- - -
10 2.8123: Pay utility bills on time $111 - - - - - $111
TOTAL RECOMMENDED $188,818 $309,194 $125,052
1,421,061
kWh
$15,720
-
kW-mo/yr
$25,315
-
MMBtu
$22,620
-
lb
$111
TOTAL IMPLEMENTED $119,773 $54,940 $89,245
1,014,147
kWh
$7,797
-
kW-mo/yr
- $22,620
-
lb
$111
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs