Assessment Year | 2021 |
---|---|
Principal Product | Skin care products |
NAICS | 325611: Soap and Other Detergent Manufacturing |
SIC | 2844: Perfumes, Cosmetics, and Other Toilet Preparations |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
95,000
ft2
|
Annual Production | 11,000,000
pieces
|
Production Hrs. Annual | 2,574
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,194 | 1,010,522 |
kWh
|
$0.048 |
Electricity Demand | $42,659 | 3,815 |
kW-mo/yr
|
$11.18 |
Electricity Fees | $24,968 | - |
|
- |
TOTAL YEARLY COSTS | $115,821 | |||
RECOMMENDED SAVINGS* | $31,930 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,232 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9112: Use solar heat to heat water | $17,031 | $8,409 |
$9,651
201,057
kWh
|
$7,380
-
kW-mo/yr
|
|
02 | 2.7232: Replace existing hvac unit with high efficiency model | $4,433 | $12,201 |
$3,270
68,125
kWh
|
$1,163
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,272 | $11,460 |
$2,047
42,636
kWh
|
$2,225
-
kW-mo/yr
|
|
04 | 2.6218: Turn off equipment when not in use | $2,753 | $3,280 |
$2,753
57,344
kWh
|
- | |
05 | 2.7135: Install occupancy sensors | $1,277 | $853 |
$1,277
26,603
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,175 | $1,980 |
$862
17,959
kWh
|
$313
-
kW-mo/yr
|
|
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $568 | $120 |
$266
5,548
kWh
|
$302
-
kW-mo/yr
|
|
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $421 | $1,231 |
$197
4,104
kWh
|
$224
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $31,930 | $39,534 |
$20,323
423,376
kWh
|
$11,607
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $30,232 | $37,450 |
$18,849
392,669
kWh
|
$11,383
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs