Assessment Year | 2019 |
---|---|
Principal Product | Stamped Metals |
NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
100,000
ft2
|
Annual Production | 500,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $212,878 | 4,813,680 |
kWh
|
$0.044 |
Electricity Demand | $181,294 | 13,709 |
kW-mo/yr
|
$13.22 |
Electricity Fees | $74,999 | - |
|
- |
Natural Gas | $1,004 | 241 |
MMBtu
|
$4.17 |
TOTAL YEARLY COSTS | $470,175 | |||
RECOMMENDED SAVINGS* | $141,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,319 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $67,585 | $640 | - | - | $67,585 | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $49,454 | $216,900 |
$35,000
795,457
kWh
|
$14,454
-
kW-mo/yr
|
- | |
03 | 2.6218: Turn off equipment when not in use | $11,441 | $3,600 |
$11,441
260,024
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,814 | $1,980 |
$2,452
55,726
kWh
|
$1,362
-
kW-mo/yr
|
- | |
05 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $2,811 | $1,120 |
$1,780
40,448
kWh
|
$1,031
-
kW-mo/yr
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,851 | $160 |
$1,190
27,056
kWh
|
$661
-
kW-mo/yr
|
- | |
07 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $1,481 | $185 |
$952
21,633
kWh
|
$529
-
kW-mo/yr
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $1,148 | $1,126 |
$725
16,487
kWh
|
$423
-
kW-mo/yr
|
- | |
09 | 2.7492: Use proper thickness of insulation on building envelope | $1,147 | $1,090 |
$724
16,459
kWh
|
$423
-
kW-mo/yr
|
- | |
10 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $288 | $187 |
$182
4,128
kWh
|
$106
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $141,020 | $226,988 |
$54,446
1,237,418
kWh
|
$18,989
-
kW-mo/yr
|
$67,585 | ||
TOTAL IMPLEMENTED | $19,319 | $8,168 |
$16,476
374,457
kWh
|
$2,843
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs