Assessment Year | 2019 |
---|---|
Principal Product | Washers and Eyelets |
NAICS | 332722: Bolt, Nut, Screw, Rivet, and Washer Manufacturing |
SIC | 3452: Bolts, Nuts, Screws, Rivets, and Washers |
Sales Range | $10 M to 50M |
# of Employees | 212 |
Plant Area |
278,000
ft2
|
Annual Production | 1,500,000,000
pieces
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,688 | 3,253,600 |
kWh
|
$0.044 |
Electricity Demand | $183,963 | 13,988 |
kW-mo/yr
|
$13.15 |
Electricity Fees | $74,440 | - |
|
- |
Natural Gas | $9,400 | 949 |
MMBtu
|
$9.91 |
TOTAL YEARLY COSTS | $411,491 | |||
RECOMMENDED SAVINGS* | $99,183 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $87,320 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $42,517 | $105,476 |
$18,937
430,386
kWh
|
$23,580
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,459 | $80,434 |
$8,506
193,329
kWh
|
$14,953
-
kW-mo/yr
|
- | |
03 | 2.6218: Turn off equipment when not in use | $12,789 | $3,600 |
$12,789
290,664
kWh
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,262 | $29,820 |
$4,082
92,779
kWh
|
$7,180
-
kW-mo/yr
|
- | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,590 | $8,800 |
$1,393
31,660
kWh
|
$1,197
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $2,156 | $2,559 |
$2,156
49,006
kWh
|
- | - | |
07 | 2.7229: Air condition only space necessary | $1,687 | $240 |
$753
17,107
kWh
|
$934
-
kW-mo/yr
|
- | |
08 | 2.7134: Use photocell controls | $1,366 | $2,206 |
$498
11,318
kWh
|
$868
-
kW-mo/yr
|
- | |
09 | 2.9112: Use solar heat to heat water | $601 | $2,205 | - | - |
$601
-
MMBtu
|
|
10 | 2.7492: Use proper thickness of insulation on building envelope | $538 | $951 |
$196
4,455
kWh
|
$342
-
kW-mo/yr
|
- | |
11 | 2.7444: Close holes and openings in building such as broken windows | $218 | $559 |
$100
2,280
kWh
|
$118
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $99,183 | $236,850 |
$49,410
1,122,984
kWh
|
$49,172
-
kW-mo/yr
|
$601
-
MMBtu
|
||
TOTAL IMPLEMENTED | $87,320 | $204,825 |
$45,328
1,030,205
kWh
|
$41,992
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs