| Assessment Year | 2018 |
|---|---|
| Principal Product | Apparel |
| NAICS | 315190: Other Apparel Knitting Mills |
| SIC | 2254: Knit Underwear and Nightwear Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 212 |
| Plant Area |
141,000
ft2
|
| Annual Production | 110,000
pieces
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Puerto Rico |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,432,885 | 8,073,604 |
kWh
|
$0.18 |
| Electricity Demand | $146,636 | 15,177 |
kW-mo/yr
|
$9.66 |
| Electricity Fees | $2,400 | - |
|
- |
| LPG | $40,877 | 1,086 |
MMBtu
|
$37.64 |
| Fuel Oil #4 | $635,460 | 56,244 |
MMBtu
|
$11.30 |
| TOTAL YEARLY COSTS | $2,258,258 | |||
| RECOMMENDED SAVINGS* | $577,462 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Fuel Oil #4 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $142,227 | $2,030 |
$132,130
746,499
kWh
|
$10,097
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $75,087 | $115,295 | - | - | - | - |
$75,087
-
MMBtu
|
- | |
| 03 | 2.2628: Utilize a less expensive cooling method | $69,002 | $300,000 |
$51,560
291,301
kWh
|
$3,942
-
kW-mo/yr
|
- | - | - | $13,500 | |
| 04 | 2.7425: Clean or color roof to reduce solar load | $59,009 | $48,268 |
$48,046
271,447
kWh
|
$10,963
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $49,949 | $6,410 |
$46,403
262,165
kWh
|
$3,546
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $49,910 | $35,323 |
$45,987
259,815
kWh
|
$3,923
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $45,466 | $38,639 |
$42,239
238,637
kWh
|
$3,227
-
kW-mo/yr
|
- | - | - | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $39,872 | $3,380 |
$37,041
209,272
kWh
|
$2,831
-
kW-mo/yr
|
- | - | - | - | |
| 09 | 2.4323: Use optimum size and capacity equipment | $24,956 | $7,314 |
$23,188
131,006
kWh
|
$1,768
-
kW-mo/yr
|
- | - | - | - | |
| 10 | 2.3212: Optimize plant power factor | $17,936 | $25,045 | - | - | $17,936 | - | - | - | |
| 11 | 2.7135: Install occupancy sensors | $3,246 | $2,109 |
$2,525
14,266
kWh
|
$721
-
kW-mo/yr
|
- | - | - | - | |
| 12 | 2.1233: Analyze flue gas for proper air/fuel ratio | $803 | $1,560 | - | - | - |
$803
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $577,462 | $585,373 |
$429,119
2,424,408
kWh
|
$41,017
-
kW-mo/yr
|
$17,936 |
$803
-
MMBtu
|
$75,087
-
MMBtu
|
$13,500 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Fuel Oil #4 Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs