Assessment Year 2018
Principal Product Paints
NAICS 325510: Paint and Coating Manufacturing
SIC 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products
Sales Range $10
M
to 50
M
# of Employees 60
Plant Area 100,000
ft2
Annual Production 1,300
Tgal
Production Hrs. Annual 2,210
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $33,105 510,720
kWh
Electricity Demand $24,077 3,010
kW-mo/yr
Electricity Fees $6,364 -
LPG $38,427 1,021
MMBtu
Waste Disposal Costs
Water Usage $16,545 2,676
Tgal
TOTAL YEARLY COSTS $118,517
RECOMMENDED SAVINGS* $24,905 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,043

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Administrative Changes Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,234 $12,519 $4,338
66,744
kWh
$2,896
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,575 $13,838 $2,735
42,083
kWh
$1,840
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,178 $2,030 $1,387
21,343
kWh
$791
-
kW-mo/yr
- -
04 2.4239: Eliminate or reduce compressed air usage $2,175 $6,578 $1,271
19,551
kWh
$904
-
kW-mo/yr
- -
05 2.6218: Turn off equipment when not in use $1,877 $1,300 $1,877
28,870
kWh
- - -
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,637 $3,750 $981
15,099
kWh
$656
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,564 $3,102 $1,564
24,068
kWh
- - -
08 2.8212: Reduce delivery schedules $1,454 $2,490 - - - $1,454
09 2.2414: Use waste heat from hot flue gases to preheat $816 $1,980 - - $816
-
MMBtu
-
10 2.1233: Analyze flue gas for proper air/fuel ratio $803 $1,560 - - $803
-
MMBtu
-
11 2.4221: Install compressor air intakes in coolest locations $592 $1,973 $355
5,459
kWh
$237
-
kW-mo/yr
- -
TOTAL RECOMMENDED $24,905 $51,120 $14,508
223,217
kWh
$7,324
-
kW-mo/yr
$1,619
-
MMBtu
$1,454
TOTAL IMPLEMENTED $13,043 $26,293 $7,918
121,823
kWh
$2,868
-
kW-mo/yr
$803
-
MMBtu
$1,454
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs