Assessment Year 2018
Principal Product Frozen fruits & vegetables
NAICS 311411: Frozen Fruit, Juice, and Vegetable Manufacturing
SIC 2037: Frozen Fruits, Fruit Juices, and Vegetables
Sales Range $10
M
to 50
M
# of Employees 20
Plant Area 22,000
ft2
Annual Production 7,300
ton
Production Hrs. Annual 2,340
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $85,735 1,625,520
kWh
Electricity Demand $30,963 2,916
kW-mo/yr
Electricity Fees $17,173 -
Waste Disposal Costs
Solid Waste (non-haz) $12,588 374,400
lb
TOTAL YEARLY COSTS $146,459
RECOMMENDED SAVINGS* $47,224 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,723

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings
01 2.2628: Utilize a less expensive cooling method $14,286 $68,000 $8,703
164,203
kWh
$2,383
-
kW-mo/yr
- $3,200
02 2.6218: Turn off equipment when not in use $12,641 $3,600 $12,641
238,502
kWh
- - -
03 2.7447: Install vinyl strip / high speed / air curtain doors $5,990 $7,485 $4,698
88,633
kWh
$1,292
-
kW-mo/yr
- -
04 2.7447: Install vinyl strip / high speed / air curtain doors $3,743 $520 $2,937
55,424
kWh
$806
-
kW-mo/yr
- -
05 3.5313: Increase amount of waste recovered for resale $3,036 $11,400 - - $3,036
-
lb
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $3,001 $8,193 $1,935
36,510
kWh
$1,066
-
kW-mo/yr
- -
07 2.8122: Use utility controlled power management $2,349 $80 - - - $2,349
08 2.7221: Lower temperature during the winter season and vice-versa $1,910 $40 $1,865
35,180
kWh
$45
-
kW-mo/yr
- -
09 2.7124: Make a practice of turning off lights when not needed $268 $40 $132
2,499
kWh
$136
-
kW-mo/yr
- -
TOTAL RECOMMENDED $47,224 $99,358 $32,911
620,951
kWh
$5,728
-
kW-mo/yr
$3,036
-
lb
$5,549
TOTAL IMPLEMENTED $24,723 $11,685 $20,276
382,559
kWh
$2,098
-
kW-mo/yr
- $2,349
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs