ITAC Assessment: MI0324
ITAC logo
ITAC Assessment: MI0324
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Surgical tools
NAICS 339112: Surgical and Medical Instrument Manufacturing
SIC 3841: Surgical and Medical Instruments and Apparatus
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 66,000
ft2
Annual Production 84,000,000
units
Production Hrs. Annual 8,568
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $581,299 3,689,275
kWh
Electricity Demand $82,454 10,572
kW-mo/yr
Electricity Fees $8,090 -
TOTAL YEARLY COSTS $671,843
RECOMMENDED SAVINGS* $182,536 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $78,765

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
01 2.2628: Utilize a less expensive cooling method $94,097 $134,000 $83,336
527,446
kWh
$5,761
-
kW-mo/yr
- $5,000
02 2.7425: Clean or color roof to reduce solar load $28,637 $15,056 $26,785
169,528
kWh
$1,852
-
kW-mo/yr
- -
03 2.3212: Optimize plant power factor $28,032 $41,300 - $28,032
-
kW-mo/yr
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $8,387 $8,923 $7,856
49,722
kWh
$531
-
kW-mo/yr
- -
05 2.8112: Combine utility meters $7,245 $100 - $4,845
-
kW-mo/yr
$2,400 -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $5,467 $4,900 $5,467
34,602
kWh
- - -
07 2.7447: Install vinyl strip / high speed / air curtain doors $3,663 $1,478 $3,430
21,706
kWh
$233
-
kW-mo/yr
- -
08 2.7135: Install occupancy sensors $3,528 $1,000 $3,528
22,327
kWh
- - -
09 2.7447: Install vinyl strip / high speed / air curtain doors $1,760 $250 $1,645
10,410
kWh
$115
-
kW-mo/yr
- -
10 2.7447: Install vinyl strip / high speed / air curtain doors $1,051 $1,722 $983
6,221
kWh
$68
-
kW-mo/yr
- -
11 2.3191: Use demand controller or load shedder $670 $100 - - $670 -
TOTAL RECOMMENDED $182,536 $208,829 $133,030
841,962
kWh
$41,437
-
kW-mo/yr
$3,070 $5,000
TOTAL IMPLEMENTED $78,765 $74,379 $48,049
304,106
kWh
$30,716
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs