Assessment Year 2017
Principal Product Plastic Tie Wraps
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 157
Plant Area 100,000
ft2
Annual Production 30,000,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $997,238 6,711,941
kWh
Electricity Demand $143,351 14,222
kW-mo/yr
Electricity Fees $10,800 -
TOTAL YEARLY COSTS $1,151,389
RECOMMENDED SAVINGS* $151,433 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $117,645

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $42,418 $1,660 $37,252
250,015
kWh
$5,166
-
kW-mo/yr
02 2.3212: Optimize plant power factor $33,420 $46,515 - $33,420
-
kW-mo/yr
03 2.7245: Use direct air supply to exhaust hoods $29,203 $11,300 $25,841
173,428
kWh
$3,362
-
kW-mo/yr
04 2.7425: Clean or color roof to reduce solar load $18,556 $8,294 $16,420
110,204
kWh
$2,136
-
kW-mo/yr
05 2.7221: Lower temperature during the winter season and vice-versa $16,568 $120 $14,661
98,396
kWh
$1,907
-
kW-mo/yr
06 2.7447: Install vinyl strip / high speed / air curtain doors $6,683 $1,885 $6,116
41,047
kWh
$567
-
kW-mo/yr
07 2.4239: Eliminate or reduce compressed air usage $4,154 $2,140 $3,549
24,502
kWh
$605
-
kW-mo/yr
08 2.2511: Insulate bare equipment $431 $151 $320
2,149
kWh
$111
-
kW-mo/yr
TOTAL RECOMMENDED $151,433 $72,065 $104,159
699,741
kWh
$47,274
-
kW-mo/yr
TOTAL IMPLEMENTED $117,645 $58,474 $74,449
499,662
kWh
$43,196
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs