| Assessment Year | 2017 |
|---|---|
| Principal Product | Zinc Coating |
| NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
| SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 28 |
| Plant Area |
20,000
ft2
|
| Annual Production | 11,000
ton
|
| Production Hrs. Annual | 3,432
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $20,757 | 434,160 |
kWh
|
$0.048 |
| Electricity Demand | $14,336 | 1,383 |
kW-mo/yr
|
$10.37 |
| Electricity Fees | $5,362 | - |
|
- |
| Natural Gas | $154,977 | 50,988 |
MMBtu
|
$3.04 |
| TOTAL YEARLY COSTS | $195,432 | |||
| RECOMMENDED SAVINGS* | $30,060 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,928 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $7,711 | $620 |
$4,228
88,088
kWh
|
$3,483
-
kW-mo/yr
|
- | |
| 02 | 2.7134: Use photocell controls | $6,519 | $720 |
$3,714
77,374
kWh
|
$2,805
-
kW-mo/yr
|
- | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,171 | $1,160 | - | - |
$6,171
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,626 | $4,300 |
$3,626
75,545
kWh
|
- | - | |
| 05 | 2.7425: Clean or color roof to reduce solar load | $2,803 | $1,580 |
$2,163
45,067
kWh
|
$640
-
kW-mo/yr
|
- | |
| 06 | 2.7442: Keep doors and windows shut when not on use | $1,082 | $249 |
$616
12,824
kWh
|
$466
-
kW-mo/yr
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $992 | $3,884 |
$471
9,795
kWh
|
$521
-
kW-mo/yr
|
- | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $992 | $1,660 |
$569
11,856
kWh
|
$423
-
kW-mo/yr
|
- | |
| 09 | 2.7135: Install occupancy sensors | $164 | $574 |
$164
3,421
kWh
|
- | - | |
| TOTAL RECOMMENDED | $30,060 | $14,747 |
$15,551
323,970
kWh
|
$8,338
-
kW-mo/yr
|
$6,171
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $14,928 | $4,363 |
$5,063
105,475
kWh
|
$3,694
-
kW-mo/yr
|
$6,171
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs