ITAC Assessment: MI0313
ITAC logo
ITAC Assessment: MI0313
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Zinc Coating
NAICS 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 28
Plant Area 20,000
ft2
Annual Production 11,000
ton
Production Hrs. Annual 3,432
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $20,757 434,160
kWh
Electricity Demand $14,336 1,383
kW-mo/yr
Electricity Fees $5,362 -
Natural Gas $154,977 50,988
MMBtu
TOTAL YEARLY COSTS $195,432
RECOMMENDED SAVINGS* $30,060 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,928

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2414: Use waste heat from hot flue gases to preheat $7,711 $620 $4,228
88,088
kWh
$3,483
-
kW-mo/yr
-
02 2.7134: Use photocell controls $6,519 $720 $3,714
77,374
kWh
$2,805
-
kW-mo/yr
-
03 2.1233: Analyze flue gas for proper air/fuel ratio $6,171 $1,160 - - $6,171
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $3,626 $4,300 $3,626
75,545
kWh
- -
05 2.7425: Clean or color roof to reduce solar load $2,803 $1,580 $2,163
45,067
kWh
$640
-
kW-mo/yr
-
06 2.7442: Keep doors and windows shut when not on use $1,082 $249 $616
12,824
kWh
$466
-
kW-mo/yr
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $992 $3,884 $471
9,795
kWh
$521
-
kW-mo/yr
-
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $992 $1,660 $569
11,856
kWh
$423
-
kW-mo/yr
-
09 2.7135: Install occupancy sensors $164 $574 $164
3,421
kWh
- -
TOTAL RECOMMENDED $30,060 $14,747 $15,551
323,970
kWh
$8,338
-
kW-mo/yr
$6,171
-
MMBtu
TOTAL IMPLEMENTED $14,928 $4,363 $5,063
105,475
kWh
$3,694
-
kW-mo/yr
$6,171
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs