Assessment Year 2016
Principal Product Wine and spirits
NAICS 312130: Wineries
SIC 2084: Wines, Brandy, and Brandy Spirits
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 65,000
ft2
Annual Production 650,000
units
Production Hrs. Annual 2,125
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $78,358 467,879
kWh
Electricity Demand $19,610 2,421
kW-mo/yr
Electricity Fees $2,718 -
TOTAL YEARLY COSTS $100,686
RECOMMENDED SAVINGS* $33,476 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,716

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.2628: Utilize a less expensive cooling method $12,170 $29,740 $10,129
60,653
kWh
$2,041
-
kW-mo/yr
02 2.6231: Utilize controls to operate equipment only when needed $4,840 $940 $4,516
27,040
kWh
$324
-
kW-mo/yr
03 2.7492: Use proper thickness of insulation on building envelope $4,045 $11,648 $3,794
22,716
kWh
$251
-
kW-mo/yr
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,652 $4,744 $2,082
12,469
kWh
$570
-
kW-mo/yr
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,711 $2,387 $2,711
14,705
kWh
-
06 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $2,171 $260 $1,685
10,089
kWh
$486
-
kW-mo/yr
07 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $2,023 $3,200 $1,897
11,357
kWh
$126
-
kW-mo/yr
08 2.7447: Install vinyl strip / high speed / air curtain doors $1,335 $416 $1,165
6,974
kWh
$170
-
kW-mo/yr
09 2.7229: Air condition only space necessary $1,008 $160 $1,008
6,034
kWh
-
10 2.7444: Close holes and openings in building such as broken windows $521 $116 $409
2,448
kWh
$112
-
kW-mo/yr
TOTAL RECOMMENDED $33,476 $53,611 $29,396
174,485
kWh
$4,080
-
kW-mo/yr
TOTAL IMPLEMENTED $24,716 $38,387 $21,611
127,875
kWh
$3,105
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings