Assessment Year | 2016 |
---|---|
Principal Product | Dental implant hardware |
NAICS | 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing |
SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
Sales Range | $50 M to 100M |
# of Employees | 256 |
Plant Area |
185,000
ft2
|
Annual Production | 1,850,000
pieces
|
Production Hrs. Annual | 5,904
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $368,775 | 7,304,400 |
kWh
|
$0.050 |
Electricity Demand | $156,362 | 13,515 |
kW-mo/yr
|
$11.57 |
Electricity Fees | $81,647 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $189,490 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $149,575 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $81,253 | $1,120 | - | - | $81,253 | - | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $50,831 | $40 |
$34,681
686,753
kWh
|
$16,150
-
kW-mo/yr
|
- | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $22,761 | $41,950 |
$3,450
69,009
kWh
|
$1,111
-
kW-mo/yr
|
- | $18,200 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,730 | $16,200 |
$5,277
104,501
kWh
|
$2,453
-
kW-mo/yr
|
- | - | |
05 | 2.7292: Lower ceiling to reduce conditioned space | $5,243 | $6,421 |
$3,577
70,848
kWh
|
$1,666
-
kW-mo/yr
|
- | - | |
06 | 2.7425: Clean or color roof to reduce solar load | $5,225 | $15,465 |
$3,559
70,466
kWh
|
$1,666
-
kW-mo/yr
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,847 | $6,880 |
$2,625
51,971
kWh
|
$1,222
-
kW-mo/yr
|
- | - | |
08 | 2.7135: Install occupancy sensors | $3,248 | $2,165 |
$3,248
64,324
kWh
|
- | - | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,622 | $40 |
$1,789
35,433
kWh
|
$833
-
kW-mo/yr
|
- | - | |
10 | 2.8114: Change rate schedules or other changes in utility service | $1,792 | $280 | - | - | - | $1,792 | |
11 | 2.7111: Reduce illumination to minimum necessary levels | $1,703 | $1,080 |
$1,159
22,955
kWh
|
$544
-
kW-mo/yr
|
- | - | |
12 | 2.7423: Reduce heat gain by window tinting | $1,443 | $2,240 |
$982
19,633
kWh
|
$462
-
kW-mo/yr
|
- | - | |
13 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,396 | $3,240 |
$952
18,845
kWh
|
$444
-
kW-mo/yr
|
- | - | |
14 | 2.7442: Keep doors and windows shut when not on use | $396 | $317 |
$303
6,059
kWh
|
$93
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $189,490 | $97,438 |
$61,602
1,220,797
kWh
|
$26,644
-
kW-mo/yr
|
$81,253 | $19,992 | ||
TOTAL IMPLEMENTED | $149,575 | $21,242 |
$46,457
920,025
kWh
|
$20,073
-
kW-mo/yr
|
$81,253 | $1,792 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs