Assessment Year 2013
Principal Product Machinery castings
NAICS 331524: Aluminum Foundries (except Die-Casting)
SIC 3369: Nonferrous Foundries, Except Aluminum and Copper
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 155,000
ft2
Annual Production 1,000
pieces
Production Hrs. Annual 3,120
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $713,367 11,445,779
kWh
Electricity Demand $252,696 24,468
kW-mo/yr
Electricity Fees $25,415 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $83,204 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $65,334

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.6218: Turn off equipment when not in use $29,537 $3,900 $24,040
387,738
kWh
$5,497
-
kW-mo/yr
02 2.6218: Turn off equipment when not in use $16,828 $2,038 $10,260
165,485
kWh
$6,568
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $16,622 $1,660 $9,935
160,236
kWh
$6,687
-
kW-mo/yr
04 2.4231: Reduce the pressure of compressed air to the minimum required $7,217 $80 $3,737
60,269
kWh
$3,480
-
kW-mo/yr
05 2.4239: Eliminate or reduce compressed air usage $6,639 $4,000 $4,048
65,284
kWh
$2,591
-
kW-mo/yr
06 2.7447: Install vinyl strip / high speed / air curtain doors $4,014 $2,406 $1,934
31,198
kWh
$2,080
-
kW-mo/yr
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,414 $1,190 $805
15,476
kWh
$609
-
kW-mo/yr
08 2.7447: Install vinyl strip / high speed / air curtain doors $933 $1,020 $561
9,048
kWh
$372
-
kW-mo/yr
TOTAL RECOMMENDED $83,204 $16,294 $55,320
894,734
kWh
$27,884
-
kW-mo/yr
TOTAL IMPLEMENTED $65,334 $9,808 $45,601
737,983
kWh
$19,733
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs