Assessment Year | 2013 |
---|---|
Principal Product | Plastic building Materials |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
85,000
ft2
|
Annual Production | 6,000,000
lb
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $123,363 | 2,543,600 |
kWh
|
$0.048 |
Electricity Demand | $83,981 | 7,184 |
kW-mo/yr
|
$11.69 |
Electricity Fees | $38,433 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $92,845 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $71,487 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $33,139 | $21,580 |
$20,900
435,409
kWh
|
$12,239
-
kW-mo/yr
|
|
02 | 2.2136: Install / repair insulation on steam lines | $11,581 | $2,980 |
$7,303
152,164
kWh
|
$4,278
-
kW-mo/yr
|
|
03 | 2.3311: Replace dc equipment with ac equipment | $10,510 | $12,640 |
$6,629
138,216
kWh
|
$3,881
-
kW-mo/yr
|
|
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $8,487 | $160 |
$5,354
111,540
kWh
|
$3,133
-
kW-mo/yr
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,459 | $1,660 |
$4,855
101,151
kWh
|
$3,604
-
kW-mo/yr
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,663 | $560 |
$3,383
80,906
kWh
|
$2,280
-
kW-mo/yr
|
|
07 | 2.6218: Turn off equipment when not in use | $5,216 | $2,600 |
$3,907
81,390
kWh
|
$1,309
-
kW-mo/yr
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,961 | $80 |
$3,007
62,646
kWh
|
$1,954
-
kW-mo/yr
|
|
09 | 2.4226: Use / purchase optimum sized compressor | $4,605 | $5,740 |
$2,449
52,464
kWh
|
$2,156
-
kW-mo/yr
|
|
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $224 | $430 |
$141
2,945
kWh
|
$83
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $92,845 | $48,430 |
$57,928
1,218,831
kWh
|
$34,917
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $71,487 | $34,720 |
$44,768
934,118
kWh
|
$26,719
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs