ITAC Assessment: MI0236
ITAC logo
ITAC Assessment: MI0236
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Food Product Machinery
NAICS 333241: Food Product Machinery Manufacturing
SIC 3589: Service Industry Machinery, Not Elsewhere Classified
Sales Range greater than $500
M
# of Employees 165
Plant Area 230,000
ft2
Annual Production 100
pieces
Production Hrs. Annual 2,080
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $138,051 1,975,590
kWh
Electricity Demand $35,166 5,060
kW-mo/yr
Electricity Fees $22,702 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $78,141 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $71,248

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $21,041 $1,660 $14,334
204,767
kWh
$6,707
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $20,939 $63,550 $13,315
190,216
kWh
$7,624
-
kW-mo/yr
03 2.6218: Turn off equipment when not in use $13,443 $1,800 $11,831
169,013
kWh
$1,612
-
kW-mo/yr
04 2.7221: Lower temperature during the winter season and vice-versa $10,720 $80 $6,814
97,344
kWh
$3,906
-
kW-mo/yr
05 2.7142: Utilize higher efficiency lamps and/or ballasts $3,825 $7,995 $3,005
42,920
kWh
$820
-
kW-mo/yr
06 2.7135: Install occupancy sensors $2,284 $400 $1,450
20,717
kWh
$834
-
kW-mo/yr
07 2.6127: Maintain air filters by cleaning or replacement $2,102 $447 $2,019
28,845
kWh
$83
-
kW-mo/yr
08 2.4231: Reduce the pressure of compressed air to the minimum required $2,087 $80 $1,552
22,176
kWh
$535
-
kW-mo/yr
09 2.7121: Utilize daylight whenever possible in lieu of artificial light $916 $40 $582
8,320
kWh
$334
-
kW-mo/yr
10 2.7447: Install vinyl strip / high speed / air curtain doors $784 $4,812 $499
7,128
kWh
$285
-
kW-mo/yr
TOTAL RECOMMENDED $78,141 $80,864 $55,401
791,446
kWh
$22,740
-
kW-mo/yr
TOTAL IMPLEMENTED $71,248 $67,657 $50,447
720,681
kWh
$20,801
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs