Assessment Year | 2013 |
---|---|
Principal Product | Food Product Machinery |
NAICS | 333241: Food Product Machinery Manufacturing |
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | greater than $500 M |
# of Employees | 165 |
Plant Area |
230,000
ft2
|
Annual Production | 100
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $138,051 | 1,975,590 |
kWh
|
$0.070 |
Electricity Demand | $35,166 | 5,060 |
kW-mo/yr
|
$6.95 |
Electricity Fees | $22,702 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $78,141 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $71,248 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $21,041 | $1,660 |
$14,334
204,767
kWh
|
$6,707
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,939 | $63,550 |
$13,315
190,216
kWh
|
$7,624
-
kW-mo/yr
|
|
03 | 2.6218: Turn off equipment when not in use | $13,443 | $1,800 |
$11,831
169,013
kWh
|
$1,612
-
kW-mo/yr
|
|
04 | 2.7221: Lower temperature during the winter season and vice-versa | $10,720 | $80 |
$6,814
97,344
kWh
|
$3,906
-
kW-mo/yr
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,825 | $7,995 |
$3,005
42,920
kWh
|
$820
-
kW-mo/yr
|
|
06 | 2.7135: Install occupancy sensors | $2,284 | $400 |
$1,450
20,717
kWh
|
$834
-
kW-mo/yr
|
|
07 | 2.6127: Maintain air filters by cleaning or replacement | $2,102 | $447 |
$2,019
28,845
kWh
|
$83
-
kW-mo/yr
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,087 | $80 |
$1,552
22,176
kWh
|
$535
-
kW-mo/yr
|
|
09 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $916 | $40 |
$582
8,320
kWh
|
$334
-
kW-mo/yr
|
|
10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $784 | $4,812 |
$499
7,128
kWh
|
$285
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $78,141 | $80,864 |
$55,401
791,446
kWh
|
$22,740
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $71,248 | $67,657 |
$50,447
720,681
kWh
|
$20,801
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs