Assessment Year | 2012 |
---|---|
Principal Product | Eyeglass Lenses |
NAICS | 339115: Ophthalmic Goods Manufacturing |
SIC | 3851: Ophthalmic Goods |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
80,000
ft2
|
Annual Production | 7,500,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Puerto Rico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $3,487,030 | 14,929,200 |
kWh
|
$0.23 |
Electricity Demand | $337,853 | 26,217 |
kW-mo/yr
|
$12.89 |
Electricity Fees | $10,800 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $617,890 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $369,380 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $185,551 | $480 |
$167,715
716,730
kWh
|
$17,836
-
kW-mo/yr
|
|
02 | 2.7425: Clean or color roof to reduce solar load | $146,160 | $70,200 |
$132,163
564,798
kWh
|
$13,997
-
kW-mo/yr
|
|
03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $88,716 | $46,097 |
$80,220
342,819
kWh
|
$8,496
-
kW-mo/yr
|
|
04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $64,249 | $12,488 |
$58,096
248,274
kWh
|
$6,153
-
kW-mo/yr
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $45,101 | $41,600 |
$40,784
174,304
kWh
|
$4,317
-
kW-mo/yr
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,707 | $1,660 |
$15,942
68,128
kWh
|
$1,765
-
kW-mo/yr
|
|
07 | 2.7496: Install partitions to reduce size of conditioned space | $15,150 | $4,720 |
$13,694
58,522
kWh
|
$1,456
-
kW-mo/yr
|
|
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,512 | $1,040 |
$9,507
40,628
kWh
|
$1,005
-
kW-mo/yr
|
|
09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $8,652 | $6,802 |
$8,046
34,383
kWh
|
$606
-
kW-mo/yr
|
|
10 | 2.2136: Install / repair insulation on steam lines | $7,962 | $1,589 |
$7,202
30,776
kWh
|
$760
-
kW-mo/yr
|
|
11 | 2.2136: Install / repair insulation on steam lines | $7,581 | $3,569 |
$6,859
29,310
kWh
|
$722
-
kW-mo/yr
|
|
12 | 2.7496: Install partitions to reduce size of conditioned space | $6,487 | $2,848 |
$5,869
25,081
kWh
|
$618
-
kW-mo/yr
|
|
13 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,524 | $80 |
$4,770
20,384
kWh
|
$754
-
kW-mo/yr
|
|
14 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $4,550 | $40 |
$4,112
17,572
kWh
|
$438
-
kW-mo/yr
|
|
15 | 2.7135: Install occupancy sensors | $2,794 | $320 |
$2,523
10,783
kWh
|
$271
-
kW-mo/yr
|
|
16 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,194 | $3,160 |
$1,078
4,607
kWh
|
$116
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $617,890 | $196,693 |
$558,580
2,387,099
kWh
|
$59,310
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $369,380 | $95,674 |
$333,874
1,426,821
kWh
|
$35,506
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs