Assessment Year 2010
Principal Product Boats
NAICS 332312: Fabricated Structural Metal Manufacturing
SIC 3441: Fabricated Structural Metal
Sales Range $1
M
to 5
M
# of Employees 27
Plant Area 220,000
ft2
Annual Production 20
pieces
Production Hrs. Annual 2,168
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $86,322 1,253,510
kWh
Electricity Demand $38,015 4,796
kW-mo/yr
Electricity Fees $18,661 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $48,519 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,944

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.3131: Reschedule plant operations or reduce load to avoid peaks $23,798 $2,550 $17,159
150,421
kWh
$6,639
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,774 $1,210 $7,769
68,152
kWh
$3,005
-
kW-mo/yr
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $3,594 $40 $2,590
22,717
kWh
$1,004
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,824 $7,562 $2,107
19,151
kWh
$717
-
kW-mo/yr
-
05 2.7447: Install vinyl strip / high speed / air curtain doors $1,359 $2,850 $968
8,803
kWh
$391
-
kW-mo/yr
-
06 3.4154: Eliminate leaks in water lines and valves $1,187 $180 - - $1,187
07 2.7221: Lower temperature during the winter season and vice-versa $4,983 $2,040 $3,556
32,328
kWh
$1,427
-
kW-mo/yr
-
TOTAL RECOMMENDED $48,519 $16,432 $34,149
301,572
kWh
$13,183
-
kW-mo/yr
$1,187
TOTAL IMPLEMENTED $16,944 $3,430 $11,325
100,480
kWh
$4,432
-
kW-mo/yr
$1,187
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs