ITAC Assessment: MI0183
ITAC logo
ITAC Assessment: MI0183
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2009
Principal Product Baked Goods
NAICS 311812: Commercial Bakeries
SIC 2051: Bread and Other Bakery Products, Except Cookies and Crackers
Sales Range $1
M
to 5
M
# of Employees 27
Plant Area 27,000
ft2
Annual Production 1,750,000
lb
Production Hrs. Annual 2,754
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $45,593 617,760
kWh
Electricity Demand $11,689 1,536
kW-mo/yr
Electricity Fees $8,439 -
Natural Gas $77,662 5,393
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,979 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,452

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
01 2.7447: Install vinyl strip / high speed / air curtain doors $11,088 $1,360 - - $11,088
-
MMBtu
-
02 2.1243: Use heat from boiler blowdown to preheat boiler feed water $5,816 $1,280 $3,997
54,757
kWh
$1,819
-
kW-mo/yr
- -
03 2.2136: Install / repair insulation on steam lines $4,012 $1,200 - - $4,012
-
MMBtu
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,501 $2,320 $1,720
23,561
kWh
$781
-
kW-mo/yr
- -
05 2.7447: Install vinyl strip / high speed / air curtain doors $1,481 $320 $1,018
13,949
kWh
$463
-
kW-mo/yr
- -
06 2.1233: Analyze flue gas for proper air/fuel ratio $1,750 $1,500 - - - $1,750
-
MMBtu
07 2.1131: Repair faulty insulation in furnaces, boilers, etc $198 $180 $136
1,862
kWh
$62
-
kW-mo/yr
- -
08 2.7447: Install vinyl strip / high speed / air curtain doors $133 $60 - - - $133
-
MMBtu
TOTAL RECOMMENDED $26,979 $8,220 $6,871
94,129
kWh
$3,125
-
kW-mo/yr
$15,100
-
MMBtu
$1,883
-
MMBtu
TOTAL IMPLEMENTED $14,452 $3,240 $1,018
13,949
kWh
$463
-
kW-mo/yr
$11,088
-
MMBtu
$1,883
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs