Assessment Year 2008
Principal Product Windows
NAICS 327215: Glass Product Manufacturing Made of Purchased Glass
SIC 3231: Glass Products, Made of Purchased Glass
Sales Range $10
M
to 50
M
# of Employees 328
Plant Area 125,000
ft2
Annual Production 18,000
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $385,445 3,307,800
kWh
Electricity Demand $87,397 11,304
kW-mo/yr
Electricity Fees $6,561 -
LPG $1,163,228 5,957,105
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $45,932 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,293

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $14,483 $21,312 $11,528
69,073
kWh
$2,955
-
kW-mo/yr
-
02 2.4322: Use or replace with energy efficient substitutes $8,156 $30,132 $6,492
38
kWh
$1,664
-
kW-mo/yr
-
03 2.7447: Install vinyl strip / high speed / air curtain doors $6,609 $1,563 - - $6,609
-
MMBtu
04 2.4231: Reduce the pressure of compressed air to the minimum required $9,203 $950 $7,150
42,814
kWh
$2,053
-
kW-mo/yr
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,034 $7,000 $1,619
9,702
kWh
$415
-
kW-mo/yr
-
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,963 $1,210 $3,141
18,817
kWh
$822
-
kW-mo/yr
-
07 2.4323: Use optimum size and capacity equipment $1,484 $4,400 $1,124
6,732
kWh
$360
-
kW-mo/yr
-
TOTAL RECOMMENDED $45,932 $66,567 $31,054
147,176
kWh
$8,269
-
kW-mo/yr
$6,609
-
MMBtu
TOTAL IMPLEMENTED $23,293 $15,123 $13,034
78,065
kWh
$3,650
-
kW-mo/yr
$6,609
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs